{"id":2175,"date":"2020-07-09T20:44:36","date_gmt":"2020-07-10T00:44:36","guid":{"rendered":"https:\/\/research.ncsu.edu\/cmif\/?page_id=2175"},"modified":"2023-08-03T11:57:30","modified_gmt":"2023-08-03T15:57:30","slug":"keyence-bz-x810","status":"publish","type":"page","link":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/","title":{"rendered":"Keyence BZ-X810"},"content":{"rendered":"\n\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/research.ncsu.edu\/cmif\/files\/2020\/07\/Keyence-set-up-resized.jpg\" alt=\"\"\/><\/figure>\n\n\n\n<p>The Keyence BZ-X810 is a fluorescence microscope for streamlined high-throughput image acquisition and batch analysis of large data sets. It supports fluorescence as well as brightfield imaging and phase contrast. The camera can be switched from monochrome to 3 CCD color mode with accurate color reproduction for histology applications. Optical sectioning in fluorescence mode is achieved by structured illumination. The system features a motorized stage, a large variety of stage inserts and comes with an incubation chamber for temperature and CO2 regulation that accommodates\u00a0 a variety of vessels including 96 well plates. Please refer to the <a href=\"https:\/\/www.keyence.com\/ss\/products\/microscope\/bz-x800_research\/\">manufacturer&#8217;s webpage<\/a> for a full list of capabilities and application examples. Our system comes with all hardware and software modules listed in the brochure. Details about our fluorescence filter sets and objective lenses are listed below.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Image and Video Gallery<\/h2>\n\n\n<div class=\"wp-block-ncst-photo-gallery has-gray-800-background-color\" id=\"ncst-photo-gallery-0\"><div class=\"ncst-photo-gallery__container\"><\/div><div class=\"ncst-photo-gallery__viewport\" aria-live=\"polite\"><div class=\"ncst-photo-gallery__viewport-reel\"><figure class=\"ncst-photo-gallery-item\" data-gallery-item=\"1\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"570\" src=\"https:\/\/research.ncsu.edu\/cmif\/files\/2020\/07\/Lupa-600.jpg\" alt=\"\" data-id=\"2191\" data-thumb-url=\"https:\/\/research.ncsu.edu\/cmif\/files\/2020\/07\/Lupa-600-300x285.jpg\" class=\"wp-image-2191\" srcset=\"https:\/\/research.ncsu.edu\/cmif\/files\/2020\/07\/Lupa-600.jpg 600w, https:\/\/research.ncsu.edu\/cmif\/files\/2020\/07\/Lupa-600-300x285.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><figcaption class=\"ncst-photo-gallery__viewport-caption\">Lupa<\/figcaption><\/figure><\/div><\/div><div class=\"ncst-photo-gallery__container\"><div class=\"ncst-photo-gallery__navigation\"><div class=\"ncst-photo-gallery__controls\"><button class=\"prev\" disabled><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M448,216.66H205.64l103.87-97.57L256,64,64,256,256,448l53.51-53.51L205.64,295.34H448Z\"><\/path><\/svg><span class=\"sr-only\">Previous Image<\/span><\/button><span class=\"ncst-photo-gallery__progress\"><span class=\"ncst-photo-gallery__current-index\">1<\/span> of 1<\/span><button class=\"next\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" viewBox=\"0 0 512 512\"><path d=\"M64,295.34H306.36L202.49,392.92,256,448,448,256,256,64l-53.51,53.51,103.87,99.15H64Z\"><\/path><\/svg><span class=\"sr-only\">Next Image<\/span><\/button><\/div><ul class=\"ncst-photo-gallery__thumbnails\"><li class=\"ncst-photo-gallery-thumb\" data-gallery-item=\"1\"><button class=\"ncst-photo-gallery__thumb-btn\" aria-label=\"(Image 1 of 1)\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"285\" src=\"https:\/\/research.ncsu.edu\/cmif\/files\/2020\/07\/Lupa-600-300x285.jpg\" alt=\"\" class=\"wp-image-2191\" data-caption=\"Lupa\" srcset=\"https:\/\/research.ncsu.edu\/cmif\/files\/2020\/07\/Lupa-600-300x285.jpg 300w, https:\/\/research.ncsu.edu\/cmif\/files\/2020\/07\/Lupa-600.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/button><\/li><\/ul><\/div><\/div><div class=\"sr-only speak-region\" aria-live=\"polite\">Lupa<\/div><\/div>\n\n\n\n\n<h2 class=\"wp-block-heading\">Filter Sets<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>DAPI: Excitation: 360\/40 nm; Emission: 460\/50 nm; Dichroic 400 nm<\/li>\n\n\n\n<li>GFP: Excitation: 470\/40 nm; Emission: 525\/50 nm; Dichroic 495 nm<\/li>\n\n\n\n<li>TRITC: Excitation: 545\/25 nm; Emission: 605\/70 nm; Dichroic 565 nm<\/li>\n\n\n\n<li>Texas Red: Excitation: 560\/40 nm; Emission: 630\/75 nm; Dichroic 585 nm<\/li>\n\n\n\n<li>Cy5: Excitation: 620\/60 nm; Emission: 700\/75 nm; Dichroic 660 nm<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Objectives<\/h2>\n\n\n\n<table id=\"tablepress-23\" class=\"tablepress tablepress-id-23\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Magnification<\/th><th class=\"column-2\">N.A. Immersion<\/th><th class=\"column-3\">Type<\/th><th class=\"column-4\">Working Distance<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2x<\/td><td class=\"column-2\">0.1<\/td><td class=\"column-3\">Plan APO <\/td><td class=\"column-4\">8.5 mm<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">10x<\/td><td class=\"column-2\">0.45<\/td><td class=\"column-3\">Plan APO <\/td><td class=\"column-4\">4 mm<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">20x<\/td><td class=\"column-2\">0.75<\/td><td class=\"column-3\">Plan APO<\/td><td class=\"column-4\">1 mm<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">60x<\/td><td class=\"column-2\">1.4 oil<\/td><td class=\"column-3\">Plan APO<\/td><td class=\"column-4\">0.13<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">20x (phase)<\/td><td class=\"column-2\">0.45<\/td><td class=\"column-3\">Plan Fluorite LD PH<\/td><td class=\"column-4\">8.2-6.9 mm<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">40x (phase)<\/td><td class=\"column-2\">0.60<\/td><td class=\"column-3\">Plan Fluorite LD PH<\/td><td class=\"column-4\">3.6-2.8 mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-23 from cache -->\n\n\n\n<h2 class=\"wp-block-heading\">Resources<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.keyence.com\/ss\/products\/microscope\/bz-x800_research\/\" target=\"_blank\" rel=\"noreferrer noopener\">Keyence webpage<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/research.ncsu.edu\/cmif\/equipment\/internal-resources-for-nc-state\/\" target=\"_blank\" rel=\"noreferrer noopener\">Resources for NC State students, faculty and staff&nbsp;<\/a>(login required)<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The Keyence BZ-X810 is a fluorescence microscope for streamlined high-throughput image acquisition and batch analysis of large data sets. It supports fluorescence as well as brightfield imaging and phase contrast.&hellip;<\/p>\n","protected":false},"author":57,"featured_media":901,"parent":534,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"ncst_custom_author":"","ncst_show_custom_author":false,"_exactmetrics_skip_tracking":false,"_exactmetrics_sitenote_active":false,"_exactmetrics_sitenote_note":"","_exactmetrics_sitenote_category":0,"ncst_dynamicHeaderBlockName":"ncst\/default-header","ncst_dynamicHeaderData":"{\"pageIntro\":\"Please read the <a href=\\\"https:\/\/research.ncsu.edu\/cmif\/user-information\/facility-policy\/\\\">facility policy<\/a> and contact <a href=\\\"mailto:cmif_microscopy@ncsu.edu\\\">CMIF<\/a> to set up an appointment.\"}","ncst_content_audit_freq":"","ncst_content_audit_date":"","ncst_content_audit_display":false,"ncst_backToTopFlag":"","footnotes":""},"tags":[],"class_list":["post-2175","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Keyence BZ-X810 - Cellular and Molecular Imaging Facility<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Keyence BZ-X810 - Cellular and Molecular Imaging Facility\" \/>\n<meta property=\"og:description\" content=\"The Keyence BZ-X810 is a fluorescence microscope for streamlined high-throughput image acquisition and batch analysis of large data sets. It supports fluorescence as well as brightfield imaging and phase contrast.&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/\" \/>\n<meta property=\"og:site_name\" content=\"Cellular and Molecular Imaging Facility\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-03T15:57:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/research.ncsu.edu\/cmif\/files\/2016\/03\/cmif-banner2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1500\" \/>\n\t<meta property=\"og:image:height\" content=\"100\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/keyence-bz-x810\\\/\",\"url\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/keyence-bz-x810\\\/\",\"name\":\"Keyence BZ-X810 - Cellular and Molecular Imaging Facility\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/keyence-bz-x810\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/keyence-bz-x810\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/files\\\/2016\\\/03\\\/cmif-banner2.jpg\",\"datePublished\":\"2020-07-10T00:44:36+00:00\",\"dateModified\":\"2023-08-03T15:57:30+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/keyence-bz-x810\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/keyence-bz-x810\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/keyence-bz-x810\\\/#primaryimage\",\"url\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/files\\\/2016\\\/03\\\/cmif-banner2.jpg\",\"contentUrl\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/files\\\/2016\\\/03\\\/cmif-banner2.jpg\",\"width\":1500,\"height\":100,\"caption\":\"Banner\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/keyence-bz-x810\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Equipment List\",\"item\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Microscopy Workstations\",\"item\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/equipment-list\\\/workstations\\\/\"},{\"@type\":\"ListItem\",\"position\":4,\"name\":\"Keyence BZ-X810\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/#website\",\"url\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/\",\"name\":\"Cellular and Molecular Imaging Facility\",\"description\":\"Welcome to CMIF\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/research.ncsu.edu\\\/cmif\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Keyence BZ-X810 - Cellular and Molecular Imaging Facility","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/","og_locale":"en_US","og_type":"article","og_title":"Keyence BZ-X810 - Cellular and Molecular Imaging Facility","og_description":"The Keyence BZ-X810 is a fluorescence microscope for streamlined high-throughput image acquisition and batch analysis of large data sets. It supports fluorescence as well as brightfield imaging and phase contrast.&hellip;","og_url":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/","og_site_name":"Cellular and Molecular Imaging Facility","article_modified_time":"2023-08-03T15:57:30+00:00","og_image":[{"width":1500,"height":100,"url":"https:\/\/research.ncsu.edu\/cmif\/files\/2016\/03\/cmif-banner2.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/","url":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/","name":"Keyence BZ-X810 - Cellular and Molecular Imaging Facility","isPartOf":{"@id":"https:\/\/research.ncsu.edu\/cmif\/#website"},"primaryImageOfPage":{"@id":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/#primaryimage"},"image":{"@id":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/#primaryimage"},"thumbnailUrl":"https:\/\/research.ncsu.edu\/cmif\/files\/2016\/03\/cmif-banner2.jpg","datePublished":"2020-07-10T00:44:36+00:00","dateModified":"2023-08-03T15:57:30+00:00","breadcrumb":{"@id":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/#primaryimage","url":"https:\/\/research.ncsu.edu\/cmif\/files\/2016\/03\/cmif-banner2.jpg","contentUrl":"https:\/\/research.ncsu.edu\/cmif\/files\/2016\/03\/cmif-banner2.jpg","width":1500,"height":100,"caption":"Banner"},{"@type":"BreadcrumbList","@id":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/keyence-bz-x810\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/research.ncsu.edu\/cmif\/"},{"@type":"ListItem","position":2,"name":"Equipment List","item":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/"},{"@type":"ListItem","position":3,"name":"Microscopy Workstations","item":"https:\/\/research.ncsu.edu\/cmif\/equipment-list\/workstations\/"},{"@type":"ListItem","position":4,"name":"Keyence BZ-X810"}]},{"@type":"WebSite","@id":"https:\/\/research.ncsu.edu\/cmif\/#website","url":"https:\/\/research.ncsu.edu\/cmif\/","name":"Cellular and Molecular Imaging Facility","description":"Welcome to CMIF","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/research.ncsu.edu\/cmif\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/pages\/2175","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/users\/57"}],"replies":[{"embeddable":true,"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/comments?post=2175"}],"version-history":[{"count":25,"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/pages\/2175\/revisions"}],"predecessor-version":[{"id":2582,"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/pages\/2175\/revisions\/2582"}],"up":[{"embeddable":true,"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/pages\/534"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/media\/901"}],"wp:attachment":[{"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/media?parent=2175"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/research.ncsu.edu\/cmif\/wp-json\/wp\/v2\/tags?post=2175"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}