{"id":66,"date":"2020-04-17T15:12:39","date_gmt":"2020-04-17T15:12:39","guid":{"rendered":"https:\/\/dev.research.ncsu.edu\/metric-alt\/?page_id=66"},"modified":"2026-05-23T18:41:36","modified_gmt":"2026-05-23T18:41:36","slug":"instrumentation","status":"publish","type":"page","link":"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/","title":{"rendered":"Instrumentation"},"content":{"rendered":"\n\n\n\n\n<h2 class=\"wp-block-heading\"><strong><strong>Mass Spectrometr<\/strong><\/strong>y<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Agilent Intuvo 9000GC \/ 5977B MSD with NIST Library and MassHunter software<\/li>\n\n\n\n<li>Agilent 6495C Triple Quadrupole Mass Spectrometers with Agilent 1290 Infinity II UHPLC system (x2, PFAS ready)<\/li>\n\n\n\n<li>Agilent 6546 Q-TOF MS w\/ high-resolution ion mobility (MOBIE SLIM by MOBILion) and Agilent 1290 Infinity II UHPLC<\/li>\n\n\n\n<li>Bruker Autoflex maX MALDI-TOF<\/li>\n\n\n\n<li>Thermo Fisher Scientific ID-X Tribrid MS and Vanquish Horizon UHPLC System<\/li>\n\n\n\n<li>Thermo Fisher Scientific Astral with Vanquish Neo UPLC system<\/li>\n\n\n\n<li>Thermo Fisher Scientific Eclipse Tribrid with ETD, PCTR, UVPD, and Vanquish Neo UPLC system<\/li>\n\n\n\n<li>Thermo Fisher Scientific Exploris 480 with Easy NanoLC 1200 System and Vanquish Horizon UHPLC<\/li>\n\n\n\n<li>Thermo Fisher Scientific Exploris 480 with Vanquish Horizon Flex UHPLC<\/li>\n\n\n\n<li>Thermo Fisher Scientific Exploris 480 with Vanquish Horizon UHPLC<\/li>\n\n\n\n<li>Thermo Fisher Scientific TSQ Altis Triple Quadrupole Mass Spectrometry w\/ Vanquish Horizon UHPLC System<\/li>\n\n\n\n<li>Thermo Fisher Scientific Exploris 240 with Custom IR-MALDESI Source (Breadboard for R&amp;D)<\/li>\n\n\n\n<li>Thermo Fisher Scientific Exploris 240 with Custom IR-MALDESI Source (System for Application)<\/li>\n\n\n\n<li>Thermo Fisher Scientific Exploris 240 with PFAS Ready Vanquish Horizon UHPLC System<\/li>\n\n\n\n<li>Thermo Fisher Scientific Orbitrap Exploris GC 240 with Headspace, SPME, and liquid autosampler and NIST and Wiley Spectral Libraries<\/li>\n\n\n\n<li>Thermo Fisher Scientific iCAP RQ ICP-MS with Ultimate 3000 LC System and an ESI SC-2DX autosampler<\/li>\n\n\n\n<li>Thermo Fisher Scientific Exactive Plus with UltiMate 3000 UHPLC System for elemental composition determinations to support synthetic chemistry<\/li>\n<\/ul>\n\n\n\n<p><strong><strong>Software for Experimental Design and Data Analysis<\/strong><\/strong><\/p>\n\n\n\n<p>Proteome Discoverer 3.3&nbsp;with Chimerys search engine, LipidSearch 5.1, Compound Discoverer 3.3 (metabolomics),&nbsp;Chromeleon 7.4 (targeted metabolomics), XCalibur 4.5 (metabolomics), and MSiReader v2.00 and RastirX for MSI Experiments. Each software suite (some with several full licenses) operates on an independent, high-performance computer with four processors. Skyline is also used extensively for targeted analyses (proteomics and small molecule) allowing for direct data sharing with project collaborators.<\/p>\n\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mr\"><strong><strong>Magnetic Resonance Spectroscopy <\/strong><\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Bruker Avance NEO 400 MHz NMR with TopSpin 4.5.0 Acquisition and Processing, RT BBO iProbe, VT, and SampleXpress Automatic Sample Changer<\/li>\n\n\n\n<li>Bruker Avance NEO 500 MHz NMR with TopSpin 4.5.0 Acquisition and Processing, BBO PRODIGY LN2-Cryoprobe, RT BBO iProbe, VT, and SampleCASE automatic Sample Changer<\/li>\n\n\n\n<li>Bruker Avance NEO 600 MHz NMR with TopSpin 4 Acquisition and Processing, RT BBO Smart Probe and TXI 1H-13C\/15N-2H Probe, VT, and SampleXpress Automatic Sample Changer<\/li>\n\n\n\n<li>Bruker Avance NEO 700 MHz NMR with TopSpin 4 Acquisition and Processing, TCI 1H\/19F-13C\/15N-2H LHe Cryoprobe, TXI 1H-13C\/15N-2H Probe, VT, and SampleXPress Automatic Sample Changer<\/li>\n\n\n\n<li>Bruker Avance III 700 MHz NMR with TopSpin 3.8 Acquisition and Processing, TCI 1H-13C\/15N-2H LHe CryoProbe, TXI 1H-13C\/15N-2H Probe, VT, and SampleXpress Automatic Sample Changer<\/li>\n\n\n\n<li>E500-10\/12 EPR System with Digital High-Resolution Hall Field Controller and Dual Channel Signal Processing Unit with nitrogen dewar and helium cryostat for low-temperature experiments.<\/li>\n\n\n\n<li>InsightMR flow system for advanced reaction monitoring.<\/li>\n<\/ul>\n\n\n\n<p><strong>Software for Data Analysis<\/strong><\/p>\n\n\n\n<p>Workstations with nmrPipe, nmrView, Topspin, and Sparky are available to users for data processing and analysis.<\/p>\n\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"xrd\"><strong><strong>X-ray Crystallography<\/strong><\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Rigaku MicroMax007 X-ray generator with Eiger 4M Detector, VariMax-VHF ArcSec Optics, Oxford Cryosystem, and associated peripherals<\/li>\n\n\n\n<li>Art Robbins Instruments Crystal Phoenix<\/li>\n\n\n\n<li>Art Robbins Instruments CrysCam Digital Microscope<\/li>\n\n\n\n<li>Leica Discovery V20 Crystallography stereomicroscope<\/li>\n\n\n\n<li>Bruker D8 Venture diffractometer using MoK\u03b1 radiation with an Oxford Cryostream 700 cold stream<\/li>\n\n\n\n<li>Leica M60 stereomicroscope, equipped with polarizing filters, rotating stage and video camera<\/li>\n<\/ul>\n\n\n\n<p><strong>Software for Data Analysis<\/strong><\/p>\n\n\n\n<p>Workstations with Cambridge Structural Database, Reciprocal Net, Phenix, COOT, CCP4, PyMol, and Chimera, are available to users for data processing and analysis.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Mass Spectrometry Software for Experimental Design and Data Analysis Proteome Discoverer 3.3&nbsp;with Chimerys search engine, LipidSearch 5.1, Compound Discoverer 3.3 (metabolomics),&nbsp;Chromeleon 7.4 (targeted metabolomics), XCalibur 4.5 (metabolomics), and MSiReader v2.00&hellip;<\/p>\n","protected":false},"author":953,"featured_media":0,"parent":28,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"ncst_custom_author":"","ncst_show_custom_author":false,"ncst_dynamicHeaderBlockName":"ncst\/default-header","ncst_dynamicHeaderData":"{}","ncst_content_audit_freq":"","ncst_content_audit_date":"","ncst_content_audit_display":false,"ncst_backToTopFlag":"","footnotes":""},"tags":[],"class_list":["post-66","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Instrumentation - METRIC<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Instrumentation - METRIC\" \/>\n<meta property=\"og:description\" content=\"Mass Spectrometry Software for Experimental Design and Data Analysis Proteome Discoverer 3.3&nbsp;with Chimerys search engine, LipidSearch 5.1, Compound Discoverer 3.3 (metabolomics),&nbsp;Chromeleon 7.4 (targeted metabolomics), XCalibur 4.5 (metabolomics), and MSiReader v2.00&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/\" \/>\n<meta property=\"og:site_name\" content=\"METRIC\" \/>\n<meta property=\"article:modified_time\" content=\"2026-05-23T18:41:36+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/about\\\/instrumentation\\\/\",\"url\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/about\\\/instrumentation\\\/\",\"name\":\"Instrumentation - METRIC\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/#website\"},\"datePublished\":\"2020-04-17T15:12:39+00:00\",\"dateModified\":\"2026-05-23T18:41:36+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/about\\\/instrumentation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/about\\\/instrumentation\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/about\\\/instrumentation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"About\",\"item\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/about\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Instrumentation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/#website\",\"url\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/\",\"name\":\"METRIC\",\"description\":\"Bring your research to the next level \",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/research.ncsu.edu\\\/metric\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Instrumentation - METRIC","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/","og_locale":"en_US","og_type":"article","og_title":"Instrumentation - METRIC","og_description":"Mass Spectrometry Software for Experimental Design and Data Analysis Proteome Discoverer 3.3&nbsp;with Chimerys search engine, LipidSearch 5.1, Compound Discoverer 3.3 (metabolomics),&nbsp;Chromeleon 7.4 (targeted metabolomics), XCalibur 4.5 (metabolomics), and MSiReader v2.00&hellip;","og_url":"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/","og_site_name":"METRIC","article_modified_time":"2026-05-23T18:41:36+00:00","twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/","url":"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/","name":"Instrumentation - METRIC","isPartOf":{"@id":"https:\/\/research.ncsu.edu\/metric\/#website"},"datePublished":"2020-04-17T15:12:39+00:00","dateModified":"2026-05-23T18:41:36+00:00","breadcrumb":{"@id":"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/research.ncsu.edu\/metric\/about\/instrumentation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/research.ncsu.edu\/metric\/"},{"@type":"ListItem","position":2,"name":"About","item":"https:\/\/research.ncsu.edu\/metric\/about\/"},{"@type":"ListItem","position":3,"name":"Instrumentation"}]},{"@type":"WebSite","@id":"https:\/\/research.ncsu.edu\/metric\/#website","url":"https:\/\/research.ncsu.edu\/metric\/","name":"METRIC","description":"Bring your research to the next level ","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/research.ncsu.edu\/metric\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/pages\/66","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/users\/953"}],"replies":[{"embeddable":true,"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/comments?post=66"}],"version-history":[{"count":13,"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/pages\/66\/revisions"}],"predecessor-version":[{"id":2407,"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/pages\/66\/revisions\/2407"}],"up":[{"embeddable":true,"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/pages\/28"}],"wp:attachment":[{"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/media?parent=66"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/research.ncsu.edu\/metric\/wp-json\/wp\/v2\/tags?post=66"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}